Image Flow Cytometer : Luminex ImageStream X MarkII
  • Up to 12 parameters
  • 4 lasers: 405 nm, 488 nm, 561 nm and 642 nm

Cytometry > Analytical cytometry > Image Flow cytometry

The image flow cytometer, Luminex ImageStream X MarkII, has 4 lasers and 2 cameras allowing to measure 12 parameters simultaneously: 2 "brightfields", 1 "darkfield SSC” and 9 fluorescence channels. 3 objectives are available x20 (1 µm / pixel), x40 (0,5 µm / pixel) et x60 (0,33 µm / pixel).

This instrument, bridging the gap between cytometry and microscopy, is ideal to study cell signaling, internalization and phagocytosis, cellular colocalization, cell morphology, cell death and autophagy and as well cell cycle and stem cells. Studies are done on very large number of cells at the single cell level with a speed of a maximum of 1000 events / second

Contact Task Facility Manager (TFM)

06 38 66 22 64

Depending structure

SFR Biosciences

50 Avenue Tony Garnier
Cedex 07
69366 Lyon
04 37 28 76 55

infos : Website

The SFR Biosciences (UMS3444/US8) provides biologists, the academic community and industry a shared pool of resources and technical core facilities specialized in four areas of expertise. These core facilities participate in projects funded at national level.

The SFR Biosciences is a Service unit that develops a strong science and technology policy for the research centers of the Charles Mérieux campus in the field of biological sciences. Today this federative structure brings together researchers from 8 contributing centers dedicated to research in the following major fields of biology: Infectious diseases, Cell biology, Plant biology, Protein biochemistry, Bioinformatics, Structural biology, Molecular evolution, Genomics, Immunology, Microbiology.

The main objective of SFR Biosciences is to develop, in close cooperation with the contributing research center in Lyon, highly efficient technological core facilities for the entire scientific

Other's Laboratory/Plateforme

Email


Laboratory : Plateau Technique AniRA-Cytométrie

Sébastien Dussurgey

Co-Responsable AniRA Cytométrie

Depending structure : SFR Biosciences
Federation :

SFR Biosciences


Lab tutorship :

CNRS/ENSLyon/Inserm/UCBL


50 avenue Tony Garnier
Cedex 07
69365 Lyon

Full support :
Continuous education :
Access with light support :
Open to academic :
Open to enterprises :

MEANS.FR

Powered by

Newsletter

Register to Fabrique de l'innovation newsletter

Copyright © 2022 Means. Tous droits réservés.
internet conception